ENVIRONMENTAL TEST CHAMBER
Model |
EC 003620 |
EC 009140 |
EC 012560 |
EC 021660 |
EC 042160 |
EC 100060 |
Test Space Volume (L) |
36 |
91 |
125 |
216 |
421 |
1000 |
Temperature Test Parameters: |
|
|||||
Temperature Range (⁰C) |
-20 to 120 |
-40 to 120 |
-60 to 120 |
-60 to 120 |
-60 to 120 |
-60 to 120 |
Temp. Constancy (⁰C) |
±1 |
±1 |
±1 |
±1 |
±1 |
±1 |
Temp. Rate (⁰C/min) |
1 |
1 |
1,3,5 |
1,3,5 |
1,3,5 |
1,3,5 |
Climate Test Parameters : |
|
|
|
|
|
|
Dew point Temp. Range (⁰C) |
+4 in (25….85) |
+4 in (25….85) |
+4 in (25….85) |
+4 in (25….85) |
+4 in (25….85) |
+4 in (25….85) |
Humidity Range (%RH) |
20 to 98 |
20 to 98 |
20 to 98 |
20 to 98 |
20 to 98 |
20 to 98 |
Humidity Constancy (%RH) |
±3 |
±3 |
±3 |
±3 |
±3 |
±3 |
Temp. Constancy (⁰C) |
±1 |
±1 |
±1 |
±1 |
±1 |
±1 |
Cooling System |
Air Cooled |
Air Cooled |
Air/Water |
Air/Water |
Air/Water |
Air/Water |
Refrigeration System |
Single |
Single |
Single/Cascade |
Single/Cascade |
Single/Cascade |
Single/Cascade |
Compressor |
Semi Hermetic |
Semi Hermetic |
Semi Hermetic |
Semi Hermetic |
Semi Hermetic |
Semi Hermetic |
Control System |
PLC with HMI |
PLC with HMI |
PLC with HMI |
PLC with HMI |
PLC with HMI |
PLC with HMI |
Test Space Dimension L X D X H |
400X300X300 |
450X450X450 |
500X500X500 |
600X600X600 |
750X750X750 |
1000X1000X1000 |
Customized Option |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
HUMIDITY TEST CHAMBER
Model |
HC 009115 |
HC 012515 |
HC 021615 |
HC 025342 |
HC 100015 |
HC 120042 |
Test Space Volume (L) |
91 |
125 |
216 |
253 |
1000 |
1200 |
Temperature Range (⁰C) |
15 to 100 |
15 to 100 |
15 to 100 |
42 to 48 |
15 to 100 |
42 to 48 |
Temp. Constancy (⁰C) |
±1 |
±1 |
±1 |
±2 |
±1 |
±2 |
Humidity Range (%RH) |
40 to 98 |
40 to 98 |
40 to 98 |
Saturated |
40 to 98 |
Saturated |
Humidity Constancy (%RH) |
±3 |
±3 |
±3 |
N/A |
±3 |
N/A |
Test Space Dimension L X D X H |
450X450X450 |
500X500X500 |
600X600X600 |
750X450X750 |
1000X1000X1000 |
1200X1000X1000 |
Customized Option |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
RAIN TEST CHAMBER
Model |
RC 0091DJP |
RC 0421DJP |
RC 1000DJP |
RC 1200JP |
RC 1728JP |
RC 8000JP |
Test Space Dimension L X D X H |
450X450X450 |
750X750X750 |
1000X1000X1000 |
1000X1000X1200 |
1200X1200X1200 |
2000X2000X2000 |
Standard |
DIN40 050:1993 & DIN EN 60 529 / JIS D0203,JSS |
JIS D0203,JSS 55555,PV-3501 |
||||
Application |
IP 1 to 6, IPX9K / JIS D 0203 R1,S1,JSS 55555- 8 Nozzles, |
JIS D 0203 R1,S1,JSS 55555- 8 Nozzles, PV 3501-1 Arc |
||||
Temperature Range (⁰C) |
Up to 80 ±5⁰C |
Up to 80 |
Up to 80 |
Ambient |
Ambient |
Ambient |
DUST TEST CHAMBER
Model |
DC 125IJ |
DC 216IJD |
DC 422IJD |
DC 1000IJD |
DC 1500ID |
DC 1728I |
Test Space Dimension L X D X H |
500X500X500 |
600X600X600 |
750X750X750 |
1000X1000X1000 |
1500X1000X1000 |
1200X1200X1200 |
Temperature Range (⁰C) |
10⁰Above ambient to 80º |
10⁰Above ambient to 80º |
10⁰ Above ambient to 80º |
10⁰Above Ambient to 80º |
10⁰ Above ambient to 80º |
10⁰Above ambient to 80º |
Temp. Constancy (⁰C) |
±4 |
±4 |
±4 |
±4 |
±4 |
±4 |
Standard |
IP5X & JSS 55555 |
IP5X & JSS 55555/D0207 |
IP5X or IP6X or IP5X & JSS 55555 or D0207 |
IP5X / IP6X / D0207 |
IP5X or IP6X |
THERMAL SHOCK CHAMBER
Model |
TC 06720 |
TC 07240 |
TC 34360 |
TC 42260 |
TC 43660 |
TC 54460 |
Test Space Volume (L) |
67 |
72 |
343 |
422 |
436 |
544 |
Temperature Range (⁰C) + |
Hot Zone |
Hot Zone |
Hot Zone |
Hot Zone |
Hot Zone |
Hot Zone |
Temperature Range (⁰C) - |
Cold Zone |
Cold Zone |
Cold Zone |
Cold Zone |
Cold Zone |
Cold Zone |
Temp. Constancy (⁰C) |
±1 |
±1 |
±1 |
±1 |
±1 |
±1 |
Basket Size L X D X H (mm) |
200X200X250 |
200X200X250 |
500X500X500 |
550X550X550 |
550X550X575 |
600X600X650 |
Basket Transfer |
˂10 Sec. |
˂10 Sec. |
˂10 Sec. |
˂10 Sec. |
˂10 Sec. |
˂10 Sec. |
Cooling Method |
Air Cooled |
Air Cooled |
Air/Water |
Air/Water |
Air/Water |
Air/Water |
Test Space Dimension L X D X H |
375X375X475 |
400X400X450 |
700X700X700 |
750X750X750 |
750X750X775 |
800X800X850 |
SALT SPRAY TEST CHAMBER
Model |
SSC 16235 |
SSC 29735 |
SSC 33035 |
SSC 39635 |
SSC 49535 |
SSC 56135 |
Test Space Volume (L) |
162 |
297 |
330 |
396 |
495 |
561 |
Temperature Range (⁰C) |
Ambient to |
Ambient to |
Ambient to |
Ambient to |
Ambient to |
Ambient to |
Temp. Constancy (⁰C) |
±1 |
±1 |
±1 |
±1 |
±1 |
±1 |
Humidity Range (%RH) |
Saturated |
Saturated |
Saturated |
Saturated |
Saturated |
Saturated |
Test Space Dimension L X D X H |
800X450X450 |
900X600X550 |
1000X600X550 |
1200X600X550 |
1500X600X550 |
1700X600X550 |
Standard |
ASTM B 117-79 |
ASTM B 117-79 |
ASTM B 117-79 |
ASTM B 117-79 |
ASTM B 117-79 |
ASTM B 117-79 |
CASS TEST CHAMBER
Model |
CC 16250 |
CC 29750 |
CC 33050 |
CC 39650 |
CC 49550 |
CC 56150 |
Test Space Volume (L) |
162 |
297 |
330 |
396 |
495 |
561 |
Temperature Range (⁰C) |
Ambient to 50 |
Ambient to 50 |
Ambient to 50 |
Ambient to 50 |
Ambient to 50 |
Ambient to 50 |
Temp. Constancy (⁰C) |
±2 |
±2 |
±2 |
±2 |
±2 |
±2 |
Humidity Range (%RH) |
Saturated |
Saturated |
Saturated |
Saturated |
Saturated |
Saturated |
Test Space Dimension L X D X H |
800X450X450 |
900X600X550 |
1000X600X550 |
1200X600X550 |
1500X600X550 |
1700X600X550 |
Standard |
DIN EN ISO 9227 CASS |
DIN EN ISO 9227 CASS |
DIN EN ISO 9227 CASS |
DIN EN ISO 9227 CASS |
DIN EN ISO 9227 CASS |
DIN EN ISO 9227 CASS |
EURO View Chamber Software
WATT View Chamber Software
SL- View Chamber Software
NI Software Features